IP·IK Ratings
IP 66/67 , IK 07/08 protection plastic enclosure
IP 66/67 , IK 09/10 protection aluminum enclosure
※ IEC(International Electrotechnical Commission) defines protection structure of electric instruments or protection boxes as follows.
| 1st Digit | Protection against solid | 2nd Digit | Protection against liquids | IK Code | Protection against mechanical impact | 
|---|---|---|---|---|---|
| IP | TEST | IP | TEST | IK | TEST | 
| 0 |  No protection | 
										0 |  No protection | 
										0 |  No protection | 
									
| 1 |  Protection against solid objects up to 50mm, e.g. accidental touch by hands. | 
										1 |  Protected against vertically falling drops of water. | 
										01 ~ 05  | 
										 Impact < 1 Joule | 
									
| 2 |  Protection against solid objects up to 12mm, e.g. fingers. | 
										2 |  Protected against direct sprays of water up to 15 ° from the vertical. | 
										06 |  Impact = 1 joule | 
									
| 3 |  Protection against solid objects over 2.5mm. (tools and wires) | 
										3 |  Protected against direct sprays of water up to 60° from the vertical. | 
										07 |  Impact = 2 joule | 
									
| 4 |  Protection against solid objects over 1mm. (tools, wires and small wire) | 
										4 |  Protected against water sprays from all directions ㅡlimited ingress permitted. | 
										08 |  Impact = 5 joule | 
									
| 5 |  Protection against dust limited ingress. | 
										5 |  Protected against low pressure jets of water from all directions ㅡ limited ingress permitted. | 
										09 |  Impact = 10 joule | 
									
| 6 |  Totally protected against dust. | 
										6 |  Protected against strong pressure jets of water from all directions ㅡlimited ingress permitted. | 
										10 |  Impact = 20 joule | 
									
| 7 |  Protected against the effects of temporary immersion between 15cm and 1m in water. | 
										||||
| 8 |  Protected against the effects of continuous immersion in water. | 
										
| 1st Digit | Protection against solid | 
|---|---|
| IP | TEST | 
| 0 |  No protection | 
									
| 1 |  Protection against solid objects up to 50mm, e.g. accidental touch by hands. | 
									
| 2 |  Protection against solid objects up to 12mm, e.g. fingers. | 
									
| 3 |  Protection against solid objects over 2.5mm. (tools and wires) | 
									
| 4 |  Protection against solid objects over 1mm. (tools, wires and small wire) | 
									
| 5 |  Protection against dust limited ingress. | 
									
| 6 |  Totally protected against dust. | 
									
| 2nd Digit | Protection against liquids | 
|---|---|
| IP | TEST | 
| 0 |  No protection | 
									
| 1 |  Protected against vertically falling drops of water. | 
									
| 2 |  Protected against direct sprays of water up to 15 ° from the vertical. | 
									
| 3 |  Protected against direct sprays of water up to 60° from the vertical. | 
									
| 4 |  Protected against water sprays from all directions ㅡlimited ingress permitted. | 
									
| 5 |  Protected against low pressure jets of water from all directions ㅡ limited ingress permitted. | 
									
| 6 |  Protected against strong pressure jets of water from all directions ㅡlimited ingress permitted. | 
									
| 7 |  Protected against the effects of temporary immersion between 15cm and 1m in water. | 
									
| 8 |  Protected against the effects of continuous immersion in water. | 
									
| IK Code | Protection against mechanical impact | 
|---|---|
| IK | TEST | 
| 0 |  No protection | 
									
| 01 ~ 05  | 
										 Impact < 1 Joule | 
									
| 06 |  Impact = 1 joule | 
									
| 07 |  Impact = 2 joule | 
									
| 08 |  Impact = 5 joule | 
									
| 09 |  Impact = 10 joule | 
									
| 10 |  Impact = 20 joule | 
									





















